Zeb-OU10KE16

Sale priceRs. 82,000.00

ZEBRONICS Online UPS is specifically designed for operations in power areas. They provide high power density with long backup time in compact size. It’s ideal for ATMs, banking and other businesses with critical applications. Users could also adjust charging current from 1A to 6A according to different applications. Comprehensive display allows easy monitoring and access of UPS status with (EPO) Emergency power off function.
Product Type: Online UPS

Features


True double-conversion

Microprocessor control optimizes reliability

Wide input voltage (110 V —300 V)

Converter mode available

ECO mode for energy saving (Only available for 1-3KVA)

Generator compatible

Smart SNMP works well with either USB or RS-232 together

Comprehensive display allows easy monitoring and access of UPS status

Input power factor correction

Adjustable battery number

Emergency power off (EPO) function
Country of Origin :  China


Specifications


MODEL ZEB-OU10KE16

Phase 1-phase in / 1-phase out

Capacity 10000 VA 8000W

INPUT

Nominal Voltage 208/220/230/240VAC

Voltage Range 110-300 VAC (Based on load at 50%) 176-300 VAC (Based on load at 100%)

Frequency Range 46~54 Hz or 56~64 Hz

Power Factor ≥0.99 @ 100% Load

OUTPUT

Output Voltage 208/220/230/240VAC

AC Voltage Regulation (Batt. Mode) ± 1%

Frequency Range (Synchronized Range) 46~54Hz

Frequency Range (Batt. Mode) 50 Hz ± 0.1 Hz

Current Crest Ratio 3:1 (max.)

Harmonic Distortion ≦ 3 % THD (Linear Load)


≦ 5 % THD (Non-linear Load

Transfer Time AC Mode to Batt. Mode : Zero


Inverter to Bypass : Zero

Waveform (Batt. Mode) Pure Sine wave

EFFICIENCY

AC Mode 93.00%

BATT Mode 91.00%

BATTERY

Numbers 16 ~ 20 (Adjustable)*

Typical Recharge Time 9hrs recover to 90% capacity

Battery Type SMF/VRLA

Charging Current (max.) 1A/2A/4A/6A (Adjustable, 6A is only available for 16pcs batteries

Charging Voltage 13.65 x N (N-Number of battery

INDICATORS

LCD Display UPS status, Load level, Battery level, Input/Output voltage, Discharge timer, and Fault conditions

ALARM

Battery Mode Sounding every 4 seconds

Low Battery Sounding every second

Overload Sounding twice every second

Fault Continuously sounding

PHYSICAL

Dimension,DxWxH (mm) 442 x 190 x 318

Net Weight (kgs) 16

ENVIRONMENT

Operation Humidity 0-95% RH @ 0-40°C (non-condensing

Noise Leve Less than 58dB @ 1 Meter

MANAGEMENT

Smart RS-232 / USB Supports Windows 2 2000/2003/XP/Vista/2008, Windows2 7/8/10, Linux and MAC

Optional SNMP Power management from SNMP manager and web browser