India’s first micro load UPS. Specially made for the security and surveillance CCTV /Broadcast studio / Medical equipments
  Voltage range of AC 140 - 290V
  ZEB Micro Load Sense system, processor based output load sensing feature, to sense micro power consumption devices
  Backup of more than 3 hours for micro power consumption devices
  Excellent microprocessor control guarantees high reliability
  Advanced 3 Tier battery management system, prolongs battery life by more than 30%.
  Made for extreme Indian Conditions.
  Rogue Equipment Connection proof – can adapt to Generators /Inverters having poor power factor as well as obsolete square wave output.
  LED & Audible alarms for instant alert signals.
  Auto restart while AC is recovering
  Simulated sine wave
  Off-mode charging
  Cold start function
  *(Under testing conditions with 1 DVR without HDD and 2 cameras without IR enabled)
  Capacity 600VA / 360W
  Input
  Voltage 220VAC
  Voltage range 140-300 VAC
  Frequency range 50Hz
  Output
  AC Voltage regulation (Batt. mode) ±10%   
  Frequency range (Batt. mode) 50Hz ±1Hz   
  Transfer time Typical 4-8ms   
  Waveform (Batt. mode)    Simulated Sine Wave   
  Battery
  Battery type & number 12 V/7Ah x 1   
  Typical recharge time 4-6 hours up to 90% capacity   
  Indicators 
  AC Mode   Green lighting   
  Battery mode  Green flashing
  Fault      N/A   
  Alarm
  Battery mode No beep till reach low voltage level   
  Low battery       Beep every second 
  Overload   Beep every 0.5 second   
  Fault       Continuously beeping   
  Protection
  Full protection Overload, discharge, and overcharge protection   
  Physical  
  Dimension, D x W x H (mm) 279 x 101 x 142   
  Net. weight (kgs) 4.2   
  Environment
  Humidity 0-90 % RH @ 0- 40°C (non-condensing)   
  Noise level Less than 40dB   
  *Product specifications are subject to change without further notice
  #Load conditions apply. CCTV surveillance system is built up with a DVR , Multi point Power supply, and the Camera array along with the distribution cable ,
all the above contribute to the main power load on the UPS , hence the Backup time varies according to system setup , make and efficiency of each
component in the system. Also the advanced Battery management system protects the full system which has an effect on the back up time.
Our results are based on lab test on system having DVR & 2 IR cameras

 