Zeb-OU1KE6

Sale price₹ 17,999.00

Inclusive of all taxes


ZEBRONICS Online UPS is specifically designed for operations in poor power areas. They provide high power density with long backup time in compact size. It’s ideal for ATMs, banking and other businesses with critical applications. Users could also adjust charging current from 1A to 6A according to different applications. Comprehensive display allows easy monitoring and access of UPS status,
Product Type: Online UPS

Features

Online Ups-1KVA
Microprocessor Based Control
LCD Display - Load Level, Battery Level, Ac Mode, Battery Mode, Bypass Mode & Fault Indicators
Generator Compatible
Wide Input Voltage Range
External Battery*
Eco Mode For Energy Saving
User Selectable Output Voltage
Zero Transfer Time
Power Management Software
Country of Origin :  China

Specifications

CAPACITY 1000 VA / 800 W
INPUT
Voltage Range
Low Line Transfer 160VAC/140VAC/120VAC/110VAC±5%
(Ambient Temp.<35°C)
(based on load percentage 100% - 80 % / 80 % - 70 % / 70 - 60 % / 60 % - 0)
Low Line comeback 175VAC/155VAC/135VAC/125VAC ± 5 %
(Ambient Temp.<35°C)
(based on load percentage 100% - 80 % / 80 % - 70 % / 70 - 60 % / 60 % - 0)
High Line Transfer 280 VAC ± 5 %
High Line Comeback 270 VAC ± 5 %
Frequency Range 40Hz ~ 70 Hz
Phase Single phase with ground
Power Factor ≥0.99 @ nominal voltage (input voltage)
OUTPUT
Output voltage 200/208/220/230/240VAC
AC Voltage Regulation ±1% (Batt. Mode)
Frequency Range 47 ~ 53 Hz or 57 ~ 63 Hz (Synchronized Range)
Frequency Range (Batt. Mode) 50 Hz ± 0.25 Hz or 60Hz ± 0.3 Hz
Overload Ambient Temp <35°C)
105%~110%: UPS shuts down after 10 minutes at battery mode or
transfer to bypass when the utility is normal. 110%~130%: UPS
shuts down after 1minute at battery mode or transfer to bypass when the utility is normal.
>130%:UPS shuts down after 3seconds at battery mode or transfer to bypass when the utility is normal.
Current Crest Ratio 3:1
Harmonic Distortion 3 % THD (linear load); = 6 % THD (non-linear load)
Transfer Time AC Mode to Batt. Mode : Zero Inverter to Bypass : 4 ms (Typical)
Waveform (Batt. Mode) Pure Sinewave
EFFICIENCY
AC Mode 88%
Battery Mode 83%
BATTERY
Numbers 3*
Recharge Time Depending On The Capacity Of External Batteries
Charging Current 1.0A/2.0A/4.0A/6.0A
Charging Voltage 41.0 VDC ±1%
PHYSICAL
Dimension 282 x 145 x 220mm (D x W x H )
Net. Weight 4.1 kg
ENVIRONMENT
Operation Humidity 20-90 % RH @ 0- 40°C (non-condensing)
Noise Level Less than 50dBA @ 1 Meter
MANAGEMENT
Smart RS-232 or USB Supports Windows® XP/Vista/7/8/10, Linux, Unix and MAC
\